Transformer pre-commissioning tests and after-receipt checks you MUST perform
Once oil filling is completed, various pre‐commissioning checks and tests are performed to ensure the healthiness of the transformer (or reactor) prior to its energization. Various electrical tests...
View ArticleInspection and maintenance of capacitor banks (recommended practices)
Capacitor banks generally require very little maintenance because they are static type of equipment, but don’t be fooled by this statement. Capacitors are well known for their dangerous reaction...
View Article6 system requirements of HV and EHV circuit breakers
With the phenomenal growth of the power system (EHV and HV) the duties that a circuit breaker is called upon to perform, besides the ability to handle short circuits, have... Read more The post 6...
View ArticleTransformer no-load loss and excitation-current measurements
A transformer dissipates a constant no-load loss as long as it is energized at constant voltage, 24 h a day, for all conditions of loading. This power loss represents a... Read more The post...
View Article7 routine tests for a dry-type transformer you should perform during...
This technical article briefly describes seven very important tests you should perform during commissioning of a dry-type transformer. Usually tests are performed in the factory where transformers are...
View Article3 most important routine tests for successful verification of a low voltage...
Individual tests or routine verifications are intended to check the essential safety aspects of LV assemblies that could be affected by hazards during mounting or possible manufacturing faults. In...
View ArticleThe most important precautions during commissioning and start up of LV...
Low voltage switchgear can often be very complex and expensive piece of electrical equipment, usually representing one of the most critical and crucial parts of the project. In order to... Read more...
View ArticleExample of 33/11 kV substation on-site assessment report
This technical article presents the shorten version of the report of an on-site assessment at the 33/11 kV Shatt Al Arab substation built in Iraq back in 2005. The assessment... Read more The post...
View ArticleTesting and commissioning of HV power transformers, circuit breakers, CTs and...
As you already know, substations are the points for controlling the supply of power on different routes by means of various equipment such as power transformers, circuit breakers, CTs/VTs,...
View ArticleThings you MUST know when commissioning low voltage switchgear and circuit...
Purchasing low voltage switchgear is not that easy, it’s not like purchasing a new TV or laptop. You have to be very experienced and deadly serious when specifying and ordering... Read more The post...
View ArticlePre-commissioning checks and tests of high voltage current transformers (CTs)
Once erection is completed, various pre-commissioning checks and tests are performed to ensure the healthiness of the switchyard equipment prior to their energization. This technical article explains...
View ArticleLessons I learned during the start-up of an MV switchgear
In the world of electrical engineering, a term start up assumes all works which are necessary to be done for putting in operation already tested switchgear, as close as possible... Read more The post...
View Article13 very important type tests of a low voltage switchgear carried out by the...
Certification of distribution assemblies is defined by international standard IEC 61439-1. This standard provides common rules that are recognized worldwide. Compliance with the standard is certified,...
View Article12 on-site checks to inspect the transformer’s health
On-site inspection of the substation transformer usually exposes important condition changes and it initiates various suspicions that need to be investigated in detail. As with any other substation...
View ArticleHow to avoid common mistakes during wiring and startup of power factor...
Power factor correction (PFC) and reactive power compensation (RPC) are often used as synonyms in practice. Although they are similar and mutually dependent terms, they don’t represent the same...
View ArticleThe art of transformer maintenance, inspection and repair (recommended...
The primary purpose of transformer maintenance is to ensure the internal and external parts of the transformer and accessories are kept in good condition and “fit for purpose” and able... Read more...
View ArticleTwelve doubts in ground testing that make electrical engineers pretty confused
Ground testing is often misunderstood by electrical engineers and technicians who do not perform such testing often and regularly. It seems that there are a lot of questions and doubts... Read more The...
View ArticleMy experience in the design and installation of medium voltage switchgears
Medium Voltage (MV) switchgear is typically any switchgear over 1000V in the United States (US). Some of the nominal voltage ratings used in the US by power utilities are 2.4-4.16kV,... Read more The...
View ArticleElectrical insulation testing – Often underestimated until things go really bad
Due to mechanical damage, vibrations, (excessive) heat/cold, moisture/humidity, chemical influences and interactions and aging pinholes, cracks causes moisture and foreign matter to penetrate the...
View ArticleHints on installation and commissioning power transformers (experience and...
Purchasing a power transformer for a project is always challenging for every electrical engineer dealing with the procurement. You could omit dozens of possible details from the final specification...
View Article